ALTI4M/B2-way 4

AUDAC-HARB
MX$ 310.76

Functional Devices RIBTPM413-BC : Power Monitor 120-277V 3-phase BACnet compatible SPECIFICATIONS Power MeterRIBPM413-BC: Power Input Rating: Powered from Line 1 to Neutral. 120-277 Vac. < 2 VAHeaders: Pluggable screw terminal. accepts up to 12 AWG stranded copper wireFrequency: 50/60 HzOperating Temperature: -4 to 158 a‚°FStorage Temperature: -40 to 185 a‚°FHumidity: 5 to 95% (noncondensing)Altitude: Up to 2.000 mRemote LED: Green = Rx Amber = TxStatus LED: See Bulletin B2646Dimensions: 2.75" x 4.5" x 0.85" with headers installedTrack Mount: MT212-4 mounting track providedApprovals:CE. UL Listed. UL 61010-1 and UL 61010-2-30. C-UL. RoHS. FCC Part 15 Class BNetwork Media: 18-22 AWG. 2-Core. shielded twisted pairNetwork Termination: For End of Line (EOL) device. use 120 aŽÂ© Resistor. See Bulletin B2646 for detailsPolarity: Network is polarity sensitiveBaud Rate: 9600. 19200. 38400. 57600. 76800. 115200; set via BACnet Metered Circuit: Voltage Range: 120277 Vac L-N (CAT III); 1P 2/3W. 3P 4WVoltage Overload: 1.1 x Voltage RangeVoltage Burden: < 0.1 VA @ 277 VacFrequency Range: 4565 HzCurrent Transformer: 333 mV Output (sold separately) Current Overload: 1.2 x CT OutputPower Overload: 1.2 x Voltage Range x CT Output Measurement Accuracy: Voltage: 0.5%. < 0.2% typical from 80-120% Current: 0.5%. < 0.2% typical from 10-120% Power: 0.5%. < 0.2% typical from 10-120%Power Factor: 0.5% between 0.5 and 1.0 Accessories:CT-25A-333. CT-50A-333. CT-100A-333 Notes: -See Bulletin B2646 for installation instructions- Bi-directional for NET metering- Order NEMA 4 housing by adding a¢â‚¬Å“-N4" to end of model number. (RIBTPM413-BC-N4)- Order with grey lid by adding a¢â‚¬Å“-GY" to end of model number. (RIBTPM413-BC-GY)- Order NEMA 4 housing with grey lid by adding a¢â‚¬Å“-N4-GY"to end of model number. (RIBTPM413-BC-N4-GY) BACnet Details: -Device ID Default: 277050-MAC Address Default: 50-Baud Rate Default: 38400-CT-Ratings (AV-8005) must be updated with the current rating of the CTs used with the device.-See Bulletin B2646 for further details Functional Devices RIBTPM413-BC Specifications

  • DELIVERY TIMES MAY VARY ACCORDING TO MANUFACTURERS' AVAILABILITY. PRICES AND MODELS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. *ITEM SUBJECT TO MANUFACTURER'S AVAILABILITY*

  • *ITEM AVAILABLE AT OUR HARBOR LOCATION*


 

Share:

Functional Devices RIBTPM413-BC : Power Monitor 120-277V 3-phase BACnet compatible SPECIFICATIONS Power MeterRIBPM413-BC: Power Input Rating: Powered from Line 1 to Neutral. 120-277 Vac. < 2 VAHeaders: Pluggable screw terminal. accepts up to 12 AWG stranded copper wireFrequency: 50/60 HzOperating Temperature: -4 to 158 a‚°FStorage Temperature: -40 to 185 a‚°FHumidity: 5 to 95% (noncondensing)Altitude: Up to 2.000 mRemote LED: Green = Rx Amber = TxStatus LED: See Bulletin B2646Dimensions: 2.75" x 4.5" x 0.85" with headers installedTrack Mount: MT212-4 mounting track providedApprovals:CE. UL Listed. UL 61010-1 and UL 61010-2-30. C-UL. RoHS. FCC Part 15 Class BNetwork Media: 18-22 AWG. 2-Core. shielded twisted pairNetwork Termination: For End of Line (EOL) device. use 120 aŽÂ© Resistor. See Bulletin B2646 for detailsPolarity: Network is polarity sensitiveBaud Rate: 9600. 19200. 38400. 57600. 76800. 115200; set via BACnet Metered Circuit: Voltage Range: 120277 Vac L-N (CAT III); 1P 2/3W. 3P 4WVoltage Overload: 1.1 x Voltage RangeVoltage Burden: < 0.1 VA @ 277 VacFrequency Range: 4565 HzCurrent Transformer: 333 mV Output (sold separately) Current Overload: 1.2 x CT OutputPower Overload: 1.2 x Voltage Range x CT Output Measurement Accuracy: Voltage: 0.5%. < 0.2% typical from 80-120% Current: 0.5%. < 0.2% typical from 10-120% Power: 0.5%. < 0.2% typical from 10-120%Power Factor: 0.5% between 0.5 and 1.0 Accessories:CT-25A-333. CT-50A-333. CT-100A-333 Notes: -See Bulletin B2646 for installation instructions- Bi-directional for NET metering- Order NEMA 4 housing by adding a¢â‚¬Å“-N4" to end of model number. (RIBTPM413-BC-N4)- Order with grey lid by adding a¢â‚¬Å“-GY" to end of model number. (RIBTPM413-BC-GY)- Order NEMA 4 housing with grey lid by adding a¢â‚¬Å“-N4-GY"to end of model number. (RIBTPM413-BC-N4-GY) BACnet Details: -Device ID Default: 277050-MAC Address Default: 50-Baud Rate Default: 38400-CT-Ratings (AV-8005) must be updated with the current rating of the CTs used with the device.-See Bulletin B2646 for further details Functional Devices RIBTPM413-BC Specifications

Connector Not specified
Water Resistant Not specified
Material Not specified
SKU SKU not available
Category BOCINAS
Tags Tags not available

Related Products